HP Integrity NonStop J-Series User Manual

Page 48

Advertising
background image

Maintenance

M8605A and M8606A ACL Tape Drive Installation and User’s Guide 546012-002

5 -2

Running a Cleaning Cartridge from a Data Cartridge

Slot

When the cleaning cycle completes, the ACL returns the cleaning cartridge back to
the mail slot magazine and the display returns to the maintenance options screen.

6. Press Back twice to return to the Default screen.

7. Use the Mail Slot Access option to remove the cleaning cartridge.

Running a Cleaning Cartridge from a Data Cartridge Slot

1. Place a cleaning cartridge into a data cartridge slot.

2. From the GUI screen, press Menu>Maintenance>Clean Drive.

3. Press the Source field and then press Slot until the slot with the cleaning tape is

shown.

4. Press the Cleaning field and then press Drive.

5. Press Execute Clean.

When the cleaning cycle completes, the ACL returns the cleaning cartridge back to
the designated slot and the display returns to the Maintenance options screen.

6. Press Back twice to return to the Default screen.

7. Remove the cleaning cartridge.

Note. Cleaning should only be done when the ACL unit displays a message informing you that
cleaning is needed.

Caution. A manual cleaning can be done but the tape cartridge must be unloaded manually
via the control panel using the execute move option. This is not a recommended option.

Advertising
This manual is related to the following products: