Replacing the p800 cache module or controller – HP Smart Array P800 Controller User Manual

Page 29

Advertising
background image

Upgrading or replacing controller options 29

Replacing the P800 cache module or controller

CAUTION:

Electrostatic discharge can damage electronic components. Be sure you are

properly grounded before beginning this procedure.

1.

Close all applications, and then power down the server. This procedure flushes all data from the
cache.

2.

Observe the BBWC Status LED ("

Battery pack LEDs

" on page

44

).

o

If the LED is blinking every 2 seconds, data is trapped in the cache. Restore system power, and
repeat the previous steps in this procedure.

o

If the LED is not lit, proceed with the next step.

WARNING:

There is a risk of explosion, fire, or personal injury if the battery pack is not

properly handled. Refer to "Battery replacement notice (on page

51

)" before installing or

removing any item that contains a battery pack.

3.

Remove the controller from the server.

4.

Pull the flanges on the battery clip outward (1), and then swivel the clip 180 degrees so that it rests
on the batteries (2).

5.

Swivel the latches on the DIMM connector outward (1).

Advertising
This manual is related to the following products: