Runtime leds for p800 model – HP Smart Array P800 Controller User Manual

Page 43

Advertising
background image

Diagnosing array problems 43

LED ID

Color

Name

Comments

9

Green

CR7: Gas Pedal

This LED, together with the Idle Task LED (next
item), indicates the amount of controller CPU

activity. For details, see the following table.

10

Green

CR8: Idle Task

This LED, together with the Gas Pedal LED (previous

item), indicates the amount of controller CPU
activity. For details, see the following table.

Gas Pedal LED

status

Idle Task LED

status

Controller CPU activity level

Off

Blinking

0–25%

Blinking Off

25–50%

On steadily

Off

50–75%

On steadily

On steadily

75–100%

Runtime LEDs for P800 model

LED ID

Color

Name

Comments

1

Green

CR502: Expander Heartbeat

This LED flashes every two seconds during normal
operation. If the LED glows steadily, the expander

cannot function due to an internal problem. If the
LED flashes twice per second, the expander

cannot function because the NVRAM is corrupt.

2

Amber

CR510: System Error

The controller ASIC has locked up and cannot
process any commands.

3

Amber

CR509: Diagnostics Error

One of the server diagnostics utilities has detected
a controller error.

4

Amber

CR500: Drive Failure

To determine which drive has failed, check the

Fault LED of each physical drive connected to the
controller.

5

Green

CR508: Activity

Port 4I is active.

Advertising
This manual is related to the following products: