Selsnpcpg, Seldisktype, Value – HP 3PAR System Reporter Software User Manual

Page 145: Example, Seldiskspeed, Selsnpcpg seldisktype, Value: example

Advertising
background image

selsnpcpg

Use the selusrcpg option to select a Common Provisioning Group (CPG) that is used for the
snap space of VVs. Usage and values are similar to selcpg (see

“selcpg” (page 144)

).

seldisktype

Use the seldisktype option to select a disk type.

value:

Specify one or more of the following:

--All Disk Types--

(Default). This value does not exclude disks based on their type.

FC

This value allows you to include only Fibre Channel type disks.

NL

This value allows you to include only Near Line type disks.

example:

The following examples show two ways to include disks regardless of type:

&seldisktype=OR&seldisktype=--All%20Disk%20Types--

The following example specifies that only Fibre Channel disks are to be included:

&seldisktype=FC

seldiskspeed

Use the seldiskspeed option to select a disk speed.

value:

Specify one or more of the following:

--All Disk Speeds--

(Default). This value does not exclude disks based on their speed.

15

This value allows you to include only 15K RPM disks.

10

This value allows you to include only 10K RPM disks.

7

This value allows you to include only 7200 RPM disks.

example:

The following examples show two ways to include disks regardless of speed:

&seldiskspeed=OR&seldiskspeed=--All%20Disk%20Speeds--

Report Options

145

Advertising
This manual is related to the following products: