Advanced topics 20

Command-line
argument

Description

/reboot_message “reboot

message”

This argument displays the specified reboot message on remote consoles

connected to the server you want to reboot. You must use this argument with
the /reboot option or the argument is ignored.

/rebooted

timeout_in_seconds

This argument delays the reboot of the server for the length of time specified

by the timeout_in_seconds variable. You must use this argument with the
/reboot option, or the argument is ignored. Acceptable values are between

15 and 3600.
The default timeout value is 15 seconds for Microsoft® Windows® operating

systems and 60 seconds for Linux.
For Linux, the Reboot Delay time is converted from seconds to minutes, and

any value under a full minute, 59 seconds or less, rounds to the next minute.

/reboot_always

If the following conditions are met, then this argument forces the server to
reboot: The /reboot_always option is selected or given as a command-

line argument.

All components selected for installation are successfully installed.

Creating Host Groups

/group “group_name”

This argument specifies an already defined group name in the HP SUM GUI.

Simulating HPSUM

/dryrun

This argument simulates the installation for a test run. Nothing is installed.

Targets

/user <username> or

/username <username>

This argument enables you to log in to HP BladeSystem c-Class Onboard

Administrator with your user ID.

/psswd <password>

This argument enables you to use the password for the user ID specified in the

/user parameter. The password is used to log in to remote hosts and HP

BladeSystem c-Class Onboard Administrators.

/current_credential This argument enables the credentials of the local host to be used as the

credentials to access the targets instead of providing the username and
password explicitly for each target. The assumption is that the current
credentials are valid for the targets being accessed. (Applies to Windows®

operating systems only.)

/target "netAddress"

This argument is the IP address or the DNS name of a HP BladeSystem c-

Class Onboard Administrator or remote host. When two Onboard
Administrators are in an enclosure, this argument should be the active

Onboard Administrator. When specifying the IP address, you can use either
the IPv4 or IPv6 format.

Capturing Log Files

/logdir "path"

This argument enables you to redirect the output from HP SUM or the HP

BladeSystem c-Class Onboard Administrator flash utility to a different
directory than the default location.

For Windows® components, the default location is

%SYSTEMDRIVE%\CPQSYSTEM\hp\log<netAddress> and the redirected
location is <path>\hp\log\<netAddress>.

For Linux components, the default location is /var/hp/log/<netAddress>

and the redirected location is <path>/hp/log/<netAddress>.

/v[erbose] or

/veryv[erbose]

These arguments enable you to set the verbosity level for the HP SUM

execution log file, hpsum_execution_log_<date>_<time>.log. Using one of