SCO UNIX Monitor Messages

Condition

Messages

Monitor starts

HP NetRAID Monitor activated

Monitor deactivated

HP NetRAID Monitor deactivated

No adapter found

No HP NetRAID Adapter found

Adapter inquiry failed

HP NetRAID inquiry failed for adapter x

Physical drive state change

Adapter: # PDrv Channel: SCSI ID # state change from
(previous state) to (new state).

Physical drive rebuilding
(when monitor starts)

Adapter: # PDrv Channel: SCSI ID# At startup is in
Rebuild state

Rebuild percentage
completed

Adapter: # PDrv Channel: SCSI ID# Rbld X% over

Rebuild failed

Adapter: # PDrv Channel: SCSI ID# Rbld failed

Rebuild over (completed)

Adapter: # PDrv Channel: SCSI ID# Rbld over

Logical drive state change

Adapter: # LDrv # state change from (previous state) to
(new state).

Logical drive state at startup

Adapter: # LDrv # state at startup is (current state)

SCO UNIX Monitor Activate/Deactivate Messages

Banyan Vines 6.0 (0) Monitor Messages

Condition

Messages

Physical drive state change

HP NetRAID Monitor Ver x.xx WARNING: Physical drive
(Host adapter #, Channel: SCSI ID #) State changed from
(previous state) to (next state).

No adapter found

HP NetRAID Monitor Ver x.xx program found no HP
NetRAID Controller.

Monitor has started for
specified adapter

HP NetRAID Monitor Ver x.xx program started for #
adapter(s).

I/O controller error

HP NetRAID Monitor Ver x.xx: Host Inquiry failed for host
adapter #, ioctl error #.

Failed to ascertain I/O status
for specified adapter

HP NetRAID Monitor Ver x.xx: Host Inquiry failed for host
adapter #, io.status #.

Unable to count number of
disks on specified adapter

HP NetRAID Monitor Ver x.xx: Failed to get number of disks
on host adapter #.