Checking s-vol consistency with the p-vol – HP XP Racks User Manual

Page 76

Advertising
background image

You can switch operations to the remote site either by deleting pairs, then reestablishing them
when recovery is completed; or by not deleting pairs. Both methods are presented below.

Procedure 28 To switch operations to the remote site by deleting pairs

1.

Record the pair status and fence level of each S-VOL.

2.

Analyze the consistency of the S-VOLs, based on pair status and P-VOL fence level setting.
See

“Checking S-VOL consistency with the P-VOL” (page 76)

.

3.

Perform file recovery as needed.

4.

Split all pairs from the S-VOLs using one of the following commands:

RAID Manager pairsplit

BCM YKSUSPND

PPRC CSUSPEND

5.

Release all pairs using one of the following commands:

RAID Manager pairsplit -S

BCM YKRECOVER

PPRC CRECOVER

If you are not using these tools, connect to each secondary system with Remote Web Console
to split and release the pairs.

NOTE:

When the S-VOL is no longer paired, it cannot be distinguished it from a

non-Continuous Access Synchronous volume. Use the appropriate means to change the S-VOL
volume labels.

6.

Complete file recovery procedures.

7.

Vary the S-VOLs online.

8.

At the remote site, start critical host operations, with the previous S-VOLs now the P-VOLs.

Procedure 29 To switch operations to the remote site by not deleting pairs

1.

Record the pair status and fence level of each S-VOL.

2.

Analyze the consistency of the S-VOLs, based on pair status and P-VOL fence level setting.
See

“Checking S-VOL consistency with the P-VOL” (page 76)

.

3.

Perform file recovery as needed.

4.

Run the RAID Manager horctakeover or pairsplit-RS on the S-VOL.

5.

Complete file recovery procedures.

6.

Vary the S-VOLs online.

7.

At the remote site, start critical host operations, with the previous S-VOLs now the P-VOLs.

Checking S-VOL consistency with the P-VOL

An S-VOL's consistency refers to whether S-VOL data is identical to data in the P-VOL. This is
dependent on your Fence Level setting, which determines whether data is copied to the P-VOL if
an error occurs during an update to the S-VOL.

76

Disaster recovery

Advertising
This manual is related to the following products: