HP Brocade 4Gb SAN Switch for HP BladeSystem p-Class User Manual

Page 37

Advertising
background image

Fabric OS 5.0.0 procedures user guide

37

For the Core Switch 2/64 and the SAN Director 2/128, the output is similar to the following:

The policy parameter determines the number of failed or inoperable units for each contributor that

triggers a status change in the switch.

Each parameter can be adjusted so that a specific threshold must be reached before that parameter

changes the overall status of a switch to

MARGINAL

or

DOWN

. For example, if the FaultyPorts DOWN

parameter is set to

3

, the status of the switch changes if 3 ports fail. Only one policy parameter needs to

pass the MARGINAL or DOWN threshold to change the overall status of the switch.

These parameters determine the status of a switch:

Number of faulty ports

Missing GBICs

Power supply status

Temperature in enclosure

Fan speed

Port status

ISL status

For detailed information about setting policy parameters, refer to the HP StorageWorks Fabric OS 4.x

Fabric Watch user guide.

To set the switch status policy threshold values:

1.

Connect to the switch and log in as admin.

2.

Issue the

switchstatuspolicyset

command.

First, the current switch status policy parameter values are displayed. Then, you are prompted to enter

values for each DOWN and MARGINAL threshold parameter:

3.

Verify the threshold settings you have configured for each parameter.

4.

Issue the

switchstatuspolicyshow

command to view your current switch status policy

configuration.

switch:admin> switchstatuspolicyshow

The current overall switch status policy parameters:

Down Marginal

----------------------------------

PowerSupplies 3 0

Temperatures 2 1

Fans 2 1

WWN 0 1

CP 0 1

Blade 0 1

Flash 0 1

MarginalPorts 2 1

FaultyPorts 2 1

MissingSFPs 0 0

switch:admin>