HP XP P9500 Storage User Manual

Page 85

Advertising
background image

oradb2 oradev22(R) (CL1-D , 2, 2-1)30053 269..SMPL ----,----- ---- -
oradb oradev2(R) (CL1-D , 2, 2) 30053 269..S-VOL PAIR,----- 267 -

Configuration definition for cascading volume pairs

The RAID Manager software (HORCM) is capable of keeping track of up to seven pair associations
per LDEV (1 for Cnt Ac-S/Cnt Ac-J, 3 for Cnt Ac-J, 3 for BC/Snapshot, 1 for Snapshot). By this
management, RAID Manager can be assigned to seven groups per LU that describes seven mirror
descriptors for a configuration definition file.

Figure 25 Mirror descriptors and group assignment

Correspondence of the configuration file and mirror descriptors

The group name and MU# which are described in HORCM_DEV of a configuration definition file
are assigned the corresponding mirror descriptors, as outlined in

Table 18 (page 85)

. “Omission

of MU#” is handled as MU#0, and the specified group is registered to MU#0 on Business Copy
and Continuous Access Synchronous. Also, the MU# that is noted for HORCM_DEV in

Table 18 (page 85)

reflects a random numbering sequence (for example, 2, 1, 0).

Table 18 Mirror descriptors and group assignments

Continuous
Access

Business Copy
(Snapshot) only

MU#0

HORCM_DEV parameter in configuration file

Journal
only

MU#1-#3

MU#1-#2

Business Copy

Continuous
Access

(MU#3-#63)

Synchronous/
Continuous
Access
Journal

-

-

oradev1

oradev1

HORCM_DEV

#dev_group dev_name port# TargetID
LU# MU#

Oradb oradev1 CL1-D 2
1

-

oradev11

oradev1

oradev1

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID
LU# MU#

Oradb oradev1 CL1-D 2
1

Oradb1 oradev11 CL1-D 2
1 1

Oradb2 oradev21 CL1-D 2
1 2

Examples of RAID Manager configurations

85

Advertising
This manual is related to the following products: