Utp cable specifications, Rj-45 pinouts and crossover function – HP NC7170 Dual Port PCI-X Gigabit Server Adapter User Manual

Page 17

Advertising
background image

Specifications

C-2

HP NC7170 Dual Port PCI-X 1000T Gigabit Server Adapter

Table C-1: NC7170 Gigabit Server Adapter Specifications

continued

Specification Description

Relative Humidity

Operating; 10% to 90%

Storage: 5% to 95%

Agency Approvals

FCC Class B

VCCI Class B

BSMI Class A

CISPR Class B

EN60950

MIC Class B

EN 55022 Class B

EN55024-1

UL

Canada UL

ICES-003 Class B

UTP Cable Specifications

To connect to the network, the NC7170 Server Adapter uses the following cable for

1000Base-T transmission.
• Category 5 UTP or better twisted-pair
• 22-26 AWG, 100Ω @ 1MHz
• EIA/TIA 568a or EIA/TIA 568b

Using UTP Category 5 Cable in Gigabit over Copper Installations

For Gigabit over copper installations, Category 5 UTP or better 1000Base-T cable must

comply with the IEEE 802.3ab 1000Base-T standard. For new installations, Category 5e

(enhanced Category 5) or better cable is recommended. Maximum distances for Gigabit over

copper cable are 100 meters (328 feet).

RJ-45 Pinouts and Crossover Function

The Ethernet standard also specifies that each segment implement a crossover function to

connect the transmitter of one device to the receiver of a device at the other end, and vice-

versa. The crossover function may be implemented internally at the hub or switch, or

externally through the twisted-pair media.