1 fibre channel switch zoning, Oss server – HP StorageWorks Scalable File Share User Manual

Page 14

Advertising
background image

Figure 1-3 OSS Server

Figure 1-3

shows a block diagram of a pair of OSS servers with two HP MSA2000fc enclosures.

1.3.1.1 Fibre Channel Switch Zoning

If your Fibre Channel is configured with a single Fibre Channel switch connected to more than
one server node failover pair and its associated MSA2000 storage devices, you must set up zoning
on the Fibre Channel switch. Most configurations are expected to require this zoning. The zoning
should be set up such that each server node failover pair only can see the MSA2000 storage
devices that are defined for it, similar to the logical view shown in

Figure 1-1 (page 12)

. The

Fibre Channel ports for each server node pair, and its associated MSA2000 storage devices should
be put into the same switch zone.

For the commands used to set up Fibre Channel switch zoning, see the documentation for your
specific Fibre Channel B-series switch available from:

http://www.hp.com/go/san