Error condition reporting – HP 3000 Enterprise Virtual Array User Manual

Page 60

Advertising
background image

Figure 19 Enclosure address bus components with enclosure ID expansion cables

1. Shelf ID expansion cable port 1—Disk enclosure 1
2. Shelf ID expansion cable port 2—Disk enclosure 2
3. Shelf ID expansion cable port 3—Disk enclosure 3
4. Shelf ID expansion cable port 4—Disk enclosure 4
5. Shelf ID expansion cable port 5—Disk enclosure 5
6. Shelf ID expansion cable port 6—Disk enclosure 6
7. Shelf ID expansion cable port 7—Controller enclosures
8. Shelf ID expansion cable port 8—Disk enclosure 8
9. Shelf ID expansion cable port 9—Disk enclosure 9
10. Shelf ID expansion cable port 10—Disk enclosure 10
11. Shelf ID expansion cable port 11—Disk enclosure 11
12. Shelf ID expansion cable port 12—Disk enclosure 12
13. Shelf ID expansion cable port 13—Disk enclosure 13

Error Condition Reporting

The EMU constantly monitors enclosure operation and notifies you of conditions that could affect

operation. When an error condition is detected, the following action is taken:

The EMU alphanumeric display is changed to Er. A condition report has precedence over all

other displays.

The audible alarm sounds (if it is not disabled).

The error is stored in the error queue.

The error is passed to the controllers for processing and display by Command View EVA.

60

Enterprise Virtual Array hardware components

Advertising