Gas Convection Oven - Electronic Control

Pg. 7.

GAS SUPPLY & INSTALLATION

GAS CONNECTION

FOR OVENS ON CASTERS

The oven must be supplied with a flexible
connector that complies with The Standard for
Connectors for Movable Gas Appliances,
ANSI
Z21.69, CGA 6.16 and addenda Z21.69a (latest
editions). A quick disconnect device must be
installed to comply with The Standard for Quick
Disconnect Devices for Use with Gas Fuel,
ANSI
Z21.41 and CAN1-6.9 (latest editions). A flexible
connector is not supplied by the factory.

Adequate means must be
provided to limit the
movement of the
appliance. Limitation of
movement must be made
without depending on the
connector, the quick
disconnect device, nor the
associated piping designed
to limit oven movement.
Mounting holes for a
restraining device are
located on the lower back
flange of the oven chassis.

S h u t t h e g a s s u p p l y

O F F

i f i t b e c o m e s

n e c e s s a r y t o d i s c o n n e c t t h e re s t r a i n t .

R e c o n n e c t t h e re s t r a i n t i m m e d i a t e l y

f o l l o w i n g t h e re t u r n o f t h e o v e n t o i t s

o r i g i n a l p o s i t i o n .

Turn the gas supply

ON

after the restraint has been reconnected.

LEAK TESTING

Use a soap and water solution on all gas supply
line connections.

CORRECT

RESTRAINT

D A N G E R

NEVER USE AN OPEN

FLAME TO LEAK TEST.