Power specifications, Environmental specifications – HP StorageWorks 20 Modular Smart Array User Manual
Page 43

Specifications
C-2
HP StorageWorks Modular Smart Array 20 User Guide
Power Specifications
Table C-3: AC Input Requirements
Nominal
Value
Range
Frequency (±5%)
50 or 60 Hz
47 to 63 Hz
Voltage
110 or 240 V
90 to 254 V RMS
(autoranging)
Steady state
maximum current
At 240 V: 1.8 A (one power supply) or 1.9 A (two
power supplies)
At 120 V: 3.7 A (one power supply) or 3.9 A (two
power supplies)
—
Standby current
0.21 A at 240 V, 60 Hz
0.15 A at 120 V, 60 Hz
—
Environmental Specifications
Table C-4: Environmental Specifications
Operating
Shipping or Storage
Ambient
temperature
10° to 35°C (50° to 95°F), with an average change
of less than 1°C per hour and a step change of
less than 3°C per hour
–40° to 66°C
–40° to 150°F
Relative humidity
(noncondensing)
40% to 60%, with a step change of less than 10%
10% to 80%
Air quality
Fewer than 500,000 particles 0.5 micron or larger
per cubic foot (approximately 17,700 per liter)
—
Heat dissipation
1175 BTU/hr (345 W)
—