Scsi id switch, Figure 5, Scsi id switch settings – HP 2120 Disk System User Manual

Page 10

Advertising
background image

HP StorageWorks Disk System 2120

10

SCSI ID Switch

The SCSI ID switch sets the address for the disk drives.

There are three possible settings for the SCSI address switch: A, B, and C. Each
setting assigns a different set of addresses to the disk modules installed in the disk
system. For SCSI address switch setting A, the addresses for the installed disk
modules are (from left to right, looking at the disk system from the front) 0, 2, 4, and
6. For SCSI address switch setting B, the addresses for the installed disk modules are
8, 10, 12, and 14. For SCSI address switch setting C, the addresses for the installed
disk modules are 9, 11, 13, and 15. See Figure 5, below.

SCSI address 7 is reserved for use by the host bus adapter.

FIGURE 5

SCSI ID Switch Settings

Note

The disk system requires a terminator when it is installed at the end
of the SCSI bus.

0

8

9

2

10

11

4

12

13

6

14

15

A

B

C

SCSI

Address

Switch

Setting

Disk Module SCSI Addresses (Viewed from front of storage enclosure)

C
B
A

Advertising