Battery-backed write cache enabler led statuses – HP ProLiant DL380 G3 Server User Manual
Page 35

Server
Component
Identification
35
Item LED
Color
1 Amber
2 Green
For LED status information, refer to "Battery-Backed Write Cache Enabler LED
Statuses (on page 35)."
Battery-Backed Write Cache Enabler LED Statuses
Server Status
LED Status
Battery Module Status
Server is on and has normal run
time
Green = On
Fast charging
Green = Off
Trickle charging
Amber = On
A short exists in the connection of one or more
of the four button cells within the battery
module
Amber = Blinking
An open exists in the circuit between the
positive and negative terminals of the battery
module
Amber = Off
Normal
Server is on and is in the first 30
seconds after power up
Green = On
Amber = On
Temporary lock-out state; data was lost due to
cable being detached
Server is off and is in data
retention mode
Amber = Blinking every
15 seconds
User data held in write cache is being backed
up
HP CONFIDENTIAL
File Name: 303130-3.doc Last Saved On: 7/7/03 1:48 PM