Battery-backed write cache enabler led statuses – HP ProLiant DL380 G3 Server User Manual

Page 35

Advertising
background image

Server

Component

Identification

35

Item LED

Color

1 Amber

2 Green

For LED status information, refer to "Battery-Backed Write Cache Enabler LED
Statuses (on page 35)."

Battery-Backed Write Cache Enabler LED Statuses

Server Status

LED Status

Battery Module Status

Server is on and has normal run
time

Green = On

Fast charging

Green = Off

Trickle charging

Amber = On

A short exists in the connection of one or more
of the four button cells within the battery
module

Amber = Blinking

An open exists in the circuit between the
positive and negative terminals of the battery
module

Amber = Off

Normal

Server is on and is in the first 30
seconds after power up

Green = On

Amber = On

Temporary lock-out state; data was lost due to
cable being detached

Server is off and is in data
retention mode

Amber = Blinking every
15 seconds

User data held in write cache is being backed
up

HP CONFIDENTIAL

File Name: 303130-3.doc Last Saved On: 7/7/03 1:48 PM