Edit ports confirm window – HP XP Racks User Manual

Page 441

Advertising
background image

Description

Item

of the CHF port as 16-Gbps. If the Auto Negotiation setting is required, the
linkup may become improper at server restart. Check a channel lamp, and
if it is blinking, remove and re-insert the cable to perform the signal
synchronization and linkup.

When the transfer speed of the CHF port is set to Auto, the data might not
be transferred at the maximum speed depending on the connected device.
Confirm the transfer speed appearing in Speed in the Ports list when you
start up the storage system, HBA, or switch. When the transfer speed is not
the maximum speed, select the maximum speed from the list on the right or
remove and reinsert the cable.

When the transfer speed of the CHF port is set to Auto, the data might not
be transferred at the maximum speed depending on the connected device.
Confirm the transfer speed appearing in Speed in the Ports list when you
start up the storage system, HBA, or switch. When the transfer speed is not
the maximum speed, select the maximum speed from the list on the right or
remove and reinsert the cable.

Select the address of the selected port.

Address (Loop ID)

Select whether a fabric switch is set to ON or OFF.

Fabric

Select the topology.

Connection Type

FC-AL: Fibre channel arbitrated loop

P-to-P (point-to-point).

Caution: Some fabric switches require that you specify point-to-point
topology. If you enable a fabric switch, check the documentation for the
fabric switch to determine whether your switch requires point-to-point
topology.

Edit Ports Confirm window

Confirm proposed settings, name the task, and then click Apply. The task will be added to the
execution queue.

Edit Ports wizard 441