Nmi functionality – HP ProLiant DL385 G2 Server User Manual

Page 15

Advertising
background image

Component identification 15

Position Default Function

S5

Off

Off = Power-on password is enabled.
On = Power-on password is disabled.

S6

Off

Off = Normal
On = ROM treats system configuration as invalid.

S7 Off

Reserved

S8 Off

Reserved

When the system maintenance switch position 6 is set to the On position, the system is prepared to erase

all system configuration settings from both CMOS and NVRAM.

CAUTION:

Clearing CMOS and/or NVRAM deletes configuration information. Be sure to

properly configure the server or data loss could occur.

NMI functionality

An NMI crash dump enables administrators to create crash dump files when a system is hung and not

responding to traditional debug mechanisms.
Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in

operating systems, device drivers, and applications. Many crashes freeze a system, and the only

available action for administrators is to cycle the system power. Resetting the system erases any

information that could support problem analysis, but the NMI feature preserves that information by
performing a memory dump before a hard reset.
To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can do any

of the following:

Short the NMI jumper pins

Press the NMI switch

Use the iLO Virtual NMI feature

For additional information, see the whitepaper on the HP website

(

http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf

).

Systems Insight Display LEDs and internal health LED

combinations

When the internal health LED on the front panel illuminates either amber or red, the server is experiencing

a health event. Combinations of illuminated system LEDs and the internal health LED indicate system

status.