Installation Instructions

ELECTRICAL REQUIREMENTS

CIRCUIT – Individual, properly polarized and grounded

15-amp branch circuit fused with 15-amp, time-delay fuse

or circuit breaker.
POWER SUPPLY – 2-wire, with ground, 120-volt,

single-phase, 60-Hz, Alternating Current.
OUTLET RECEPTACLE – Properly

grounded 3-prong receptacle to be

located so the power supply cord

is accessible when the washer is

in an installed position.

WARNING:

Improper connection of the

equipment-grounding conductor can result in a risk

of electrical shock. Check with a licensed electrician

if you are in doubt as to whether the appliance is

properly grounded.

1.

The

washer

MUST be grounded. In the event of

malfunction or breakdown, grounding will reduce

the risk of electrical shock by providing a path of least

resistance for electrical current.

2. Since your washer is equipped with a power supply

cord having an equipment-grounding conductor and

a grounding plug, the plug MUST be plugged into an

appropriate, copper-wired receptacle that is properly

installed and grounded in accordance with all local

codes and ordinances or in the absence of local codes,

with the National Electrical Codes, ANSI/NFPA 70 (latest

edition). If in doubt, call a licensed electrician. DO NOT

cut off or alter the grounding prong on the power

supply cord. In situations where a two-slot receptacle is

present, it is the owner’s responsibility to have a licensed

electrician replace it with a properly grounded

three-prong, grounding-type receptacle.

Read these instructions completely

and carefully.

GROUNDING REQUIREMENTS

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within

42 inches (107 cm) of your washer’s water inlet. The faucets

MUST be 3/4” (1.9 cm) garden hose-type so inlet hoses

can be connected. Water pressure MUST be between 10

and 120 pounds per square inch. Your water department

can advise you of your water pressure. The hot water

temperature should be set to deliver water at 120° to 140°F

(48°–60°C)

to provide proper Automatic Temperature Control (ATC)

performance.

DRAIN REQUIREMENTS

1. Drain capable of eliminating 9.5 gals (36 L) per minute.
2. A standpipe diameter of 1-1/4” (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 30” (76 cm)

Maximum height: 96” (244 cm)

To achieve a drain height

above 58” (147 cm), to a

maximum of 96”, a service

kit must be purchased

through GE Service

(WH49X301).

NOTE: The drain hose attached to the washer can reach

a 58”-high standpipe. For a higher standpipe, contact an

authorized parts distributor.

:$51,1*³

TO REDUCE THE RISK OF

FIRE, ELECTRICAL SHOCK AND PERSONAL INJURY:

• DO NOT USE AN EXTENSION CORD OR AN ADAPTER

PLUG WITH THIS APPLIANCE.

Washer must be electrically grounded in accordance

with local codes and ordinances or, in the absence

of local codes, in accordance with the NATIONAL

ELECTRICAL CODE, ANSI/NFPA NO. 70.