Installation Instructions

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within

42 inches (107 cm) of your washers water inlet. The faucets

MUST be 3/4s (1.9 cm) garden hose-type so inlet hoses can

be connected. Water pressure MUST be between 10 and 120

pounds per square inch. Your water department can advise

you of your water pressure. The hot water temperature

should be set to deliver water at 120° to 140°F (48°–60°C)

to provide proper Automatic Temperature Control (ATC)

performance.
NOTE: A water softener is recommended to reduce buildup of

scale inside the steam generator if the home water supply is

very hard.

DRAIN REQUIREMENTS

1. Drain capable of eliminating 17 gals (64.3 L)

per minute.

2. A standpipe diameter of 1 1/4s (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 24s (61 cm)

Maximum height: 96s (244 cm)

NOTE: The drain hose attached to the washer can reach

a 58s (147 cm) high standpipe. For a higher standpipe,

contact an authorized parts distributor.

BACK

96” (8 ft.)

(244 cm)

Max.

24” (2 ft.)

(61 cm)

Min.

INSTALLING THE WASHER

1. Run some water from the hot and cold faucets to flush the

water lines and remove particles that might clog the inlet

hose and water valve screens.

2. Remove the inlet hoses from the packaging.
3. (90° elbow end) Ensure there is a rubber washer in the

90° elbow end of the HOT

and COLD hoses. Reinstall

the rubber washer into the

hose fitting if it has fallen out

during shipment. Carefully

connect the inlet hose

marked HOT to the outside

“H” outlet of the water valve.

Tighten by hand, then tighten

another 2/3 turn with pliers.

Carefully connect the other inlet hose to the inside “C” outlet

of the water valve. Tighten by hand; then tighten another

2/3 turn with pliers. Do not crossthread or over-tighten

these connections.

4. If inlet hose screen washers are not already inserted into

the inlet hoses, install them by inserting into the free ends

of the HOT and COLD inlet hoses with protruded side facing

the faucet.

5. Connect the inlet hose ends to the HOT and COLD

water faucets tightly by hand, then tighten another

2/3 turn with pliers. Turn the water on and check

for leaks.

6. Carefully move the washer to its final location. Gently rock

the washer into position. It is important not to damage the

rubber leveling legs when moving your washer to its final

location. Damaged legs can increase washer vibration. It

may be helpful to spray window cleaner on the floor to help

move your washer into its final position.

NOTE: To reduce vibration, ensure that all four rubber

leveling legs are firmly touching the floor. Push and pull

on the back right and then back left of your washer.
NOTE: Do not use the dispenser drawer or door to lift

the washer.

NOTE: If you are installing into a drain pan, you can use

a 24-inch long 2x4 to lever the washer into place.

C

H

Inlet Hose

Screen

Washers