Installation Instructions

REQUIREMENTS FOR ALCOVE OR

CLOSET INSTALLATION

MOBILE OR MANUFACTURED HOME

INSTALLATION

14

- Explosion Hazard

WARNING

Keep flammable materials and vapors, such as gasoline,

away from dryer.
Place dryer at least 18” (46 cm) above the floor for a

garage installation.
Failure to do so can result in death, explosion, or fire.

•

Installation must conform to the

MANUFACTURED HOME CONSTRUCTION AND

SAFETY STANDARD, TITLE 24, PART 32–80 or

Standard CAN/CSA-Z240 MH, or, when such

standard is not applicable, with AMERICAN

NATIONAL STANDARD FOR MOBILE HOME,

ANSI/NFPA NO. 501B.

•

The dryer MUST be vented to the outdoors. The

exhaust vent must be securely fastened to a

non-combustible portion of the mobile home.

•

The vent MUST NOT be terminated beneath a

mobile or manufactured home.

•

The vent duct material MUST BE METAL.

•

KIT 14-D346-33 MUST be used to attach the dryer

securely to the structure.

•

The vent MUST NOT be connected to any other

duct, vent or chimney.

•

Do not use sheet metal screws or other

fastening devices which extend into the interior

of the exhaust vent.

•

Provide an opening with a free area of at least

25 square inches for introduction of outside air

into the dryer room.

•

See the sections for electrical connection

information.

•

If the dryer is approved for installation in an

alcove or closet, it will be stated on a label on the

dryer back.

•

The dryer MUST be vented to the outdoors.

•

Minimum clearance between dryer cabinet and

adjacent walls or other surfaces is:

0”

either

side

3”

front

3”

rear

1”

top

52” from floor to overhead cabinets

•

Consideration must be given to provide adequate

clearance for installation and service.

•

Closet ventilation openings required: 2 louvers

each 60 square inches (387 square cm), located 3

inches (7.6 cm) from top and bottom of door.

Gas Dryers Only:
•

No other fuel burning appliance shall be installed

in the same closet as a gas dryer.

•

The dryer must be disconnected from the gas

supply piping during pressure testing at pressures

greater than ½ psi (3.5 kPa).

•

A 1/8 inch NPT minimum plugged tapping,

accessible for test gauge connection, must be

installed immediately upstream of the gas supply

connection to the dryer.