GE GTDL740GDWW User Manual

Gtdl740gd, 8 cu. ft. capacity long-venting gas dryer

Advertising
background image

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

geappliances.com or call GE Answer Center

®

service, 800.626.2000.

Dimensions and Installation Information (in inches)

370170

Specification Revised 3/14

GTDL740GD

GE

®

7.8 cu. ft. capacity long-venting gas dryer

Exhaust Options:

2-way via rear and bottom. Dryer is shipped exhausted to the rear.

Alternate exhausting knockouts are supplied.
Gas: An individual properly-grounded branch circuit, with a three-prong

grounding-type receptacle, protected by a 15 or 20 amp circuit breaker

or a time-delay fuse is required.
Gas Dryer Electric Rating: 120V, 60Hz, 9A
Gas (BTU/HR): 16,000. Factory-equipped for natural gas. Tested for

LP gas. LP gas supply requires a conversion kit. Check installation

instructions for correct kit and have a qualified gas technician install a

conversion kit. See dryer ducting information for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry

and accessible when dryer is mounted in position.
Installation Information: For complete information, see installation

instructions packed with your dryer.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the

dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side

3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of

open area equally distributed. If this closet contains both a washer and a dryer, doors must contain

a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes, with the

National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides

3" rear