An air gap protects your dishwasher against water

backing up into it if a drain clogs. The air gap is not

a part of the dishwasher. It is not covered by your

warranty. Not all plumbing codes require air gaps,

so you may not have one.

The air gap is easy to clean.

1

Turn off the dishwasher and lift off the air gap

cover.

2

Remove the plastic cap under the cover and

clean with a toothpick.

3

Replace the cap and cover when the air gap is

clean.

Does Your Dishwasher Have an Air Gap?

If your dishwasher is left in an unheated place

during the winter, ask a service technician to:

1

Turn off electrical power to the dishwasher.

Remove fuses or trip circuit breaker.

2

Turn off the water supply and disconnect the

water inlet line from the water valve.

3

Drain water from the water inlet line and

water valve. (Use a pan to catch the water.)

4

Reconnect the water inlet line to the water

valve.

Protect Against Freezing

Check the air gap any

time your dishwasher

isn’t draining well.

Air gap

Main filter

Fine
filter

Cup

Cleaning the Filters

Inspect and clean the filters periodically. This should

be done every month. If there is a decrease in

wash performance or dishes feel gritty, this is

also an indication the filters need to be cleaned.
To clean the filters, remove the bottom rack.

Lift out the main filter and cup assembly. Lift

out the fine filter.

Rinse the main filter, fine filter and cup with

warm soapy water. Scouring pads or brushes

can scratch the filter surface but a soft brush

or sponge may be needed to remove stubborn

soils or calcium deposits caused by hard water.
Once cleaned replace the fine filter followed

by the cup and main filter assembly. Be sure to

press them in place as improper replacement

of the filter may reduce the performance level

of the appliance.

Care

and cleaning.

GEAppliances.com

14

Cleaning the Spray Arms

Because hard water chemicals will clog the spray

arm jets and bearings, it is necessary to clean the

spray arms regularly. To remove the spray arm,

twist the retaining nut 90 degrees and pull the

spray arm off the shaft.

Wash the arms in soapy, warm water and use a

soft brush to clean the jets. Replace them after

rinsing thoroughly.