zv48Tsfss – GE Monogram 48" stainless steel Professional Hood

Optional Duct Cover Accessories

Decorative duct covers are available in 6" and 12" heights. Duct covers may be

stacked, in various combinations, to conceal the ductwork running from the

top of the hood to the ceiling.
• Before you begin, you should determine the installation height of the hood

and order the correct size duct cover. The duct covers should be ordered at

the same time as the vent hood and be on site before

installation. Order the duct cover corresponding to your model.

6" Duct Cover

12" Duct Cover

6" Duct Covers

Hood Model

6" Duct Cover

Dimensions

ZV48T, ZV48S

ZX48DC6

6"H x 19-11/16"W x 11-7/8"D

ZV36T, ZV36S

ZX36DC6

6"H x 15-3/4"W x 11-7/8"D

ZV30T, ZV30S

ZX36DC6

6"H x 15-3/4"W x 11-7/8"D

12" Duct Covers

Hood Model

12" Duct Cover Dimensions

ZV48T, ZV48S

ZX48DC12

12"H x 19-11/16"W x 11-7/8"D

ZV36T, ZV36S

ZX36DC12

12"H x 15-3/4"W x 11-7/8"D

ZV30T, ZV30S

ZX36DC12

12"H x 15-3/4"W x 11-7/8"D

For answers to your Monogram,

®

GE Profile

or

GE appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center

®

service, 800.626.2000.

Listed by

Underwriters

Laboratories

Advanced Planning

Ductwork Planning
• These vent hoods are equipped for 10" round ductwork. In most instances

they may be transitioned to 8" round.

• This hood may be vented vertically through upper cabinets, soffit or ceiling.

A duct transition piece is supplied for vertical exhaust. Use locally supplied

elbows to vent horizontally through the rear wall.

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For satisfactory

performance, duct run should not exceed 150 ft. equivalent length for

any duct configurations.

• Refer to “Duct Fittings” chart to compute the maximum permissible length

for duct runs to the outdoors.

• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior opening. Order

the wall or roof cap and any transition needed in advance.

Wall framing for Adequate support
• These vent hoods are heavy. Adequate structural support must be provided.

Hoods must be secured to vertical studs in the wall.

• It is strongly recommended that the vent hood with duct cover be on site

before final framing and wall finishing. This will also help to accurately

locate the ductwork and electrical service.

Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available to fit all models. The

duct cover conceals the ductwork running from the top of the hood to the

ceiling or soffit. Stack one or more duct covers over the top of the hood

to reach your ceiling height.

POWER suPPly

IMPORTAnT – (Please read carefully)

WARNING:

FOR PERSOnAL SAFETY, THIS APPLIAnCE MUST BE

PROPERLY GROUnDED.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this appliance. Follow

national electrical codes or prevailing local codes and ordinances

.

Electric supply

These vent hoods must be supplied with 120V, 60Hz, and connected to an

individual, properly grounded branch circuit, and protected by a 15 or 20 amp

circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above requirements, call a

licensed electrician before proceeding.

• Route house wiring as close to the installation location as possible on the

back wall or ceiling.

• Connect the wiring to the house wiring in accordance with local codes.

Grounding instructions

The grounding conductor must be connected to a ground metal, permanent

wiring system, or an equipment-grounded terminal or lead on the hood.

WARNING:

The improper connection of the equipment-grounding

conductor can result in a risk of electric shock. Check with a qualified

electrician or service representative if you are in doubt whether the appliance

is properly grounded.

specification Revised 6/11