Design Guide

THE INSTALLATION SPACE

Free-Standing – Use canopy top Built-In – Remove canopy top

(if needed)

Choose the location:

• This product has been designed as a free-standing unit;

however, if desired, it may also be built-in.

• These products may be closed in on the top and

three sides as long as the front is unobstructed for

air circulation and proper access to the door.

• Do not operate these products where the temperature

will go below 45°F (7°C) or above 120°F (49°C).

• Unit must be installed on a structurally sound and

level surface strong enough to support a fully loaded

refrigerator, or approx. 250 lbs.

• The Outdoor/Indoor Refrigerator can be used

free-standing.

*For a standard installation: The product must be installed

so that the stainless steel front will project 1-7/8" forward
of adjacent cabinets. This position will allow a full door swing
and prevent interference with adjacent cabinetry.
The opening between cabinets must be 23-3/4" minimum.

**For a flush installation: Install a 1/2"-wide filler strip on

the hinge side. The filler strip will act as a spacer between
the door case and adjacent cabinets and will prevent
interference with the cabinet door swing. Recess the filler
strip 1-7/8" back from the front face of the refrigerator, or
even with the front edge of the product case (behind the
gasket). The width of the opening must be 24-1/2" (including
the 1/2" filler strip).

Additional Specifications

• A 120 volt 60Hz., 15 or 20 amp power supply is

required. An individual properly grounded branch circuit

or circuit breaker is recommended. Install a properly

grounded 3-prong electrical receptacle recessed into

the back wall as shown. Electrical must be located

on rear wall as shown.

THIS PRODUCT MUST BE

CONNECTED TO A POWER SOURCE WITH GROUND

FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION

WHEN INSTALLED IN AN OUTDOOR LOCATION. LOCAL

CODES MAY REQUIRE A SEPARATE CIRCUIT.

THE INSTALLATION SPACE (cont.)

These products will fit flush

to adjacent cabinets when

installed with a 1/2" filler panel

or cleat. The filler panel should

be recessed or set back behind

the door and even with the front

edge of the product case.

In a standard installation,

the product will project 1-7/8"

forward of adjacent cabinets.

Flush

Installation

CABINET

CABINET

CABINET

CABINET

1-7/8"

1/2"

120°

120°

110°

110°

Filler panel or cleat

to be set back even

with front of case.

Front edge of product case

Front face

Front face

Front edge of product case

Standard

Installation

NOTE:

Handle and

handle standoff

depth is 2-7/8"