Asm 7.0 faq (frequently asked questions) – Acer ASM 7 User Manual

Page 29

Advertising
background image

ASM 7.0 FAQ (Frequently Asked Questions)

29 of 29

Acer Confidential

is required. Please follow the procedure to perform a post-installation for hardware sensors reading in
Linux.

a.

Insert ASM 7.0 CDROM

b.

Login as root

c.

Copy lmsensor file

# mount /mnt/cdrom

# cp /mnt/cdrom/ism/Software/linux/lmsensors.tar.gz /usr/src

NOTE: For ASM 7.0 build 200

T

(or later), the lmsensor file is in the folder of

/mnt/cdrom/ism/Software/linux/32bit/server/lm85

d.

Install lmsensor file

# cd /usr/src

# tar –zxvf lmsensors.tar.gz

# cd msensors

# ./install.sh

When finished, sensors-detect will configure the lm85 sensors to /etc/lm85.conf and /etc/rc*.

10.

I’ve successfully installed ASM 7.0 Windows Agent on Altos G530. But, all the sensors information in ASM
7.0, such as fans, temperatures or voltages, are all zero. I replaced the main-board, but the problem is still.

ANSWER: During the installation of ASM 7 Agent of Windows, if users click “No” when installing SMBus
driver, then this problem might occur.