Page 6

AXIS 231D+/232D+ Installation Guide

Connection Module Pinout

Digital Input (1-4) - connect to GND to activate or leave floating (unconnected) to deactivate

Transistor Output (1-4) - Max. load 100mA, max. voltage 24V DC. An open-collector NPN transistor
with the emitter connected to pin 2 (GND). If used with an external relay, a diode must be connected
in parallel with the load for protection against any voltage transients.

LED indicators

Important!

The AXIS 231D+/232D+ is designed for indoor and outdoor use. To use the
camera outdoors, it must be installed in an approved outdoor housing. Please see
www.axis.com for more information on outdoor housings.
Do not use the camera’s dome bubble if it is to be installed in a protective
housing as the use of two dome bubbles will reduce the image quality and cause
image blurring.

Function

Description

Function

Description

n/a

not used

GND

ground

n/a

not used

GND

ground

n/a

not used

Transistor Output 4

See below

n/a

not used

Digital Input 4

See below

n/a

not used

Transistor Output 3

See below

n/a

not used

Digital Input 3

See below

n/a

not used

Transistor Output 2

See below

PS GND

ground

Transistor Output 1

See below

24 VAC

24 VAC

Digital Input 2

See below

24 VAC

24 VAC

Digital Input 1

See below

LED

Color

Description

Network

Green

Steady for connection to 100 Mbit/s network. Flashes for network activity.

Amber

Steady for connection to 10 Mbit/s network. Flashes for network activity.

Unlit

No connection.

Power

Green

Normal operation.

Amber

Flashes green/amber during firmware upgrade.

!