American Fibertek MRX-8489C-SL User Manual

Page 9

Advertising
background image

9

MRX-8489C-SL STATUS INDICATORS

The MRX-8489C-SL receiver provides the following front panel LED status indicators to aid in
installation and troubleshooting:

DATA

These indicators turn green when any data activity is present. An active DATA TX LED indicates
data is present at the input terminals to the MRX-8489C-SL. An active DATA RX LED indicates
data is present at the output terminals of the MRX-8489C-SL. When configured for contact
closure, the Tx and Rx LEDs will be off to indicate contact open and on to indicate contact
closed. When configured for RS-485, an active Hi-Z LED indicates the MRX-8489C-SL has
seized the data line to allow data flow. The intensity of the indicators will vary with input data
patterns, however, the Hi-Z LED will typically appear dimmer than the data Tx and Rx LEDs.
The data channels associated with these front panel DATA LEDs are listed below.

Configuration Protocol

DATA 1 TX

DATA 1 RX

DATA 2 TX

DATA 2 RX

RS485

RS485 Tx

RS485 Rx

Hi-Z

Hi-Z

RS422

RS422 Tx

RS422 Rx

Not Used

Not Used

Contact Closure

Not Used

Not Used

Contact State

Contact State

RS422/Contact Closure

RS422 Tx

RS422 Rx

Contact State

Contact State

OLI 1

A bi-color LED indicator monitors the power of the optical input signal that is being received at
the MRX-8489C-SL from video channels one through four of the MTX-8489C-SL. AC power and
optical input status associated with this LED are summarized below. Please note that data is
sent as a subcarrier on channel one’s video signal.

Optical Level Indicator

AC Power Status

Optical Status

Green

On

Proper Optical Input Power Present

Red

On

Optical Input Not Detected

Off

Off

Check Power Supply Input

Advertising
This manual is related to the following products: