American Fibertek MXR2-SM-LX-ST User Manual

Page 6

Advertising
background image

6

MX2 / MXR2 STATUS INDICATORS

The MX2 / MXR2 series units provide the following LED status indicators to aid in troubleshooting:


PWR

A green LED indicator monitors the presence of DC power into the unit. Power status associated with
this LED is summarized below.

PWR Indicator:

Power Status:

Green

Input Power at Correct Level

Off

Check Input Power


FX Link

A Green LED indicator monitors the fiber connection and data flow on the fiber port. Fiber status
associated with this LED is summarized below:

FX Link Indicator:

Fiber Port Status:

Solid Green

Fiber Connected

Flashing Green

Fiber Port Communicating in 1000 Mbps Mode

Off

Fiber Not Connected


Link/ACT1

A Green LED indicator monitors the copper connection and data flow on copper port #1. Port status
associated with this LED is summarized below:

Link/ACT1 Indicator:

Port 1 Status:

Solid Green

Port 1 Connected

Flashing Green

Port 1 Communicating

Off

No Data Flow


SPD1

A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #1. Data status
associated with this LED is summarized below:

SPD1 Indicator:

Port 1 Status:

Green

Port 1 Connected and in 1000 Mbps Mode

Amber

Port 1 Connected and in 100 Mbps Mode

Off

Port 1 Connected and in 10 Mbps Mode


Link/ACT2

A Green LED indicator monitors the copper connection and data flow on copper port #2. Port status
associated with this LED is summarized below:

Link/ACT2 Indicator:

Port 2 Status:

Solid Green

Port 2 Connected

Flashing Green

Port 2 Communicating

Off

No Data Flow


SPD2

A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #2. Data status
associated with this LED is summarized below:

SPD2 Indicator:

Port 2 Status:

Green

Port 2 Connected and in 1000 Mbps Mode

Amber

Port 2 Connected and in 100 Mbps Mode

Off

Port 2 Connected and in 10 Mbps Mode