Antec EARTHWATTS 750 User Manual

Page 4

Advertising
background image

T

ABLE

3:

O

UTPUT

C

APACITY AND

R

EGULATION

Output

Voltage

Load Max.

Regulation

Ripple & Noise

+3.3V

25A

±5%

50 mV

+5V

25A

±5%

50 mV

+12V

1

40A

±5%

120 mV

+12V

2

40A

±5%

120 mV

+12V

3

40A

±5%

120 mV

+12V

4

40A

±5%

120 mV

–12V

0.5A

±10%

120 mV

+5Vsb

3A

±5%

50 mV


The continuous maximum total output power shall not exceed 750W.

+12V

1-4

DC maximum output power shall not exceed 750W.

+3.3V and +5V DC maximum combined output power shall not exceed 150W.





I

NSTALLATION

:

1.

Install the EA-750 Green PSU into your case with the four screws provided.















Advertising