Retrieving codes – Equus 3145 - Digital Ford Code Reader (1981 - 1995) User Manual

Page 69

Advertising
background image

Retrieving Codes

KOEO SELF TEST (MCU SYSTEMS)

Chapter 4

66

■

In-Line 4 and In-Line 6 with canister control
valve:
Remove hose from connector port B. Reconnect
after testing is completed.

■

V-6 and V-8: Remove PCV valve: Reconnect after
testing is completed.

■

2.3L with GK code: Locate the anti-backfire vacuum
switch tee behind the MCU module and remove the
cap. Reconnect after testing is completed.

■

2.3L with EGR vacuum load control valve: Cover
vacuum valve vent holes with tape. Remove the tape
after testing is completed.

■

4.2L with vacuum delay valve: Uncap restrictor in
Thermactor Air Diverter (TAD) solenoid vacuum line.
Reconnect after testing is completed.

■

5.8L with vacuum delay valve: Uncap restrictor in
Thermactor Air Bypass (TAB) solenoid vacuum line.
Reconnect after testing is completed.

KEY ON ENGINE OFF (KOEO) SELF TEST (MCU
SYSTEMS)

•

The "Preliminary Procedures" (page 66) must be
completed before performing the KOEO Self Test

•

Always observe safety precautions before and during
testing process.

•

ALWAYS check Code Reader battery before retrieving
fault codes.

•

Fix any known mechanical problems before this test.

1.

Warm-up engine to normal operating temperature before
this test.

2.

Turn ignition off.

3.

Turn the Code Reader switch to OFF then connect it to
the vehicle's test connector.

■

MCU Systems have one six pin connector only.

4

Advertising