Operating your remote control, Transmitter operation – King of Fans Covington User Manual

Page 12

Advertising
background image

CAUTION - This device complies with
part 15 of the FCC rules. Operation is
subject to the following two conditions.
(1)This device may not cause harmful
interference and (2) This device must
accept

any

interference

received,

including interference that may cause
undesired operation.

Transmitter Operation

NOTE:

Be sure to install 4 fresh

1.5-volt batteries(not included)

Fan- Pressing this button steps

through the various fan speeds "High",
"Med.", "Low" and "Off". The fan speed
is displayed on the LCD screen.

Light - Pressing this button activates

the light On and Off.

For/Rev- Reverses the fan's direction of
rotation.

Timer ºC / ºF- Automatically turns the
fan/ light off after a pre-selected amount
of time. Press the Timer button followed
by the Up and Down buttons to adjust the
time delay before the fan/light turns off.

To select Fahrenheit or Celsius, press
Timer button for at least 10 seconds.

Light Delay

- Pressing

this button

activates the light delay function. The
light will automatically shut off after 3
minutes.

Fan Auto and Temp./Set (Up and Down)
-Pressing the Fan Auto button places the
fan in automatic fan control mode. In this
mode the fan speed is automatically set
on "High", "Med." Or "Low" speed
depending upon the room temperature
and the user selected temperature set
point. Press the Temp Set Up and Down
buttons

to

select

the

desired

room

temperature. If the room temperature is
less than the set point then the fan turns
off, if the room temperature is within 3
degree F over/or equal to the set point
then the fan will be on "Low" speed. As
the room temperature increases the fan
will automatically switch to "Med" and
then "High" speed. For every 4 degree F
over the set temperature, the fan will
switch to the next higher speed.

Wall Mount- Your remote control model
comes with a holder included for the
transmitter which can be mounted on a
convenient location on a wall. (Figure 18).
The

holder

will

help

prevent

your

transmitter from being misplaced.
The remote control monitors the air
temperature to automatically control the
fan speed. Ideally local the control on an
interior wall where it will accurately read
the air temperature away from direct sun
or other heat sources.

FAN AUTO MODE SET POINT EXAMPLE:

SUMMER

WINTER

SET POINT

72º

75º

78º

80º

OFF

72º

74º

77º

79º

LOW

72º-75º 75º-78º 78º-81º 80º-83º

MED

76º-79º 79º-82º 82º-85º 84º-87º

HI

80º+

83º+

86º+

88º+

10.Operating Your Remote Control