Network - snmp, Network - upnp, Network - rtp (multicast)/mpeg-4 – Axis Communications AXIS 221 User Manual

Page 42: Network - bonjour, Ports & devices

Advertising
background image

42

AXIS 221 - System Options

Network - SNMP

The Simple Network Management Protocol (SNMP) allows the remote management of

network devices. Select the version of SNMP to use, depending on the level of security

required. HTTPS should be enabled when setting the password for SNMPv3.

Network - UPnP™

The camera includes support for UPnP

, which is enabled by default. If also enabled on

your computer, the camera will automatically be detected and a new icon will be added to

“My Network Places.”

Note:

UPnP must also be enabled on your Windows XP or ME computer. To do this, open the Control Panel from
the

Start Menu and select Add/Remove Programs. Select Add/Remove Windows Components and open

the

Networking Services section. Click Details and then select UPnP as the service to add.

Network - RTP (Multicast)/MPEG-4

These settings are the IP address, port number, and Time-To-Live value to use for the video

stream(s) in multicast MPEG-4 format. Only certain IP addresses and port numbers should

be used for multicast streams. For more information, please see the online help.

Network - Bonjour

The AXIS 225FD includes support for Bonjour. When enabled, the camera is automatically

detected by operating systems and clients that support Bonjour.

Ports & Devices

I/O Ports

The two alarm inputs and one output on the AXIS 221 can be connected to various

external devices, e.g. door sensors and alarm bells. The name given to the ports can be

changed and state of the I/O ports can be set to Open circuit or Closed circuit.

The pinout, interface support and the control and monitoring functions provided by this

connector are described in Unit Connectors, on page 46.

COM Ports RS-485/422 & RS-232

The RS-485/422 and RS-232 connectors can also be configured to allow them to be

controlled by TCP/IP applications. The TCP/IP parameters are described in the online help.

It is possible to configure COM Ports RS-485/422 and RS-232 for Pan/Tilt/Zoom (PTZ)

functionaliy, but only with additional third party hardware and a compatible PTZ driver.

For more information, please contact support at www.axis.com