SPECIFICATIONS
Vacuum Tubes:
2X 5751, 1X 6414, 1X 7044
Fuse Type
2 AMP SLO-BLO
Lamp type
1/4 X 1 1/4, 12 volt, .15 amp
MIC PRE SECTION
Gain
46 dB maximum
Frequency Response @ -1 dB
10 Hz to 25 kHz
@ -2 dB
5 Hz to 60 kHz
Maximum Output
+28 dBm, +24 dBm (1K load)
Noise floor @ maximum gain
-72 dBm typical (tubes vary)
Signal to Noise
100 dB typical
Distortion @ +10 dBm / 1 kHz / open load
.025 %
Input Impedance
2400 ohms
Output Impedance
300 ohms
LINE AMP & EQ SECTION
Gain
9 dB maximum (no eq)
Frequency Response @ -1 dB
10 Hz to 25 kHz
@ -2 dB
8 Hz to 35 kHz
Maximum Output
+28 dBm, +24 dBm (1K load)
Noise floor @ maximum gain
-70 dBm typical
Signal to Noise
98 dB typical
Distortion @ +10 dBm / 1 kHz / open load
.004 %
Input Impedance
1000 ohms
Output Impedance
30 ohms typical
MIC IN TO LINE OUT
Frequency Response @ -1 dB
10 Hz to 20 kHz
Signal to Noise
95 dB
Distortion
.03%
Size
19" X 12" X 3.5" (2U)
Power Consumption
60 Watts (500 mA @ 120VAC)
Shipping Weight
15 pounds
MIC EQ 500 COMBO