MJM Yachts 40z Express User Manual

Page 32

Advertising
background image

CHAPTER 6

Check to see that AC volts are
now reading on the digital meter
over AC Panel 2 by throwing the
toggle switch between the digital
displays to “Shore 2”.

TURN BREAKERS ON for the
items you wish to operate.

Note: if the generator starts, but

no AC voltage is seen at the
panel, check first that the selector
switches (sliding interlocks) at the
top of the AC panel are ON. If so,
there is a possibility the
generator was overloaded and
the AC breaker on the generator
Control Box has tripped due to a
momentary overload. Open the
generator cover and reset (pull
up) the AC Output Circuit
Breaker

TO STOP: Remove electrical
load from the generator by
turning off all breakers. Allow the
generator to run for a 3-5 minute
cool-down period. Depress STOP
momentarily on the lower part of
the rocker switch.

Generator Fuel Pre-Filter is
located behind the genset
against the bulkhead.

GENSET WATER SEPARATOR DISHCHARGE THRU HULL
Located outboard of engine compartment to starboaard

- 31 -

ELECTRICAL SYSTEM

Advertising
This manual is related to the following products: