Trouble shooting, Other specification – XIGMATEK NRP-MC651 User Manual

Page 15

Advertising
background image

55A max. when AC input 115Vac at 25

cold start.

110A max. when AC input 230Vac at 25

cold start.

Inrush Current:

80% (min.) at full load (typical) and 115Vac input

Power Efficiency

1.

Conducted EMI

•Meet FCC: Class B

•Meet CISPR 2 2: Class B

•Meet BSMI: Class B

2.

Safety Standards

•Meet CUL (UL 60950)

•Meet TUV En60950

•Meet CB (IE C 950)

•Meet CE

3.

Harmonic Meet IEC1000-3-2, Class D

CE Requirements

No DC output. The fan or fans are motionless. Check:

•Is the AC inlet plug firmly plugged into the PSU inlet socket?

•Is the wall socket, extension power cord, power strip or surge protector in use, fully

functional and wall power switch turned ‘ON’?

•Is the Main Board socket (20+4 pin) plug fully and firmly inserted?

Condition 1:

The fan or fans began rotating and then stopped. The system hangs without

proceeding any further. Check:
•Are the peripheral connectors firmly plugged into accessory devices, such as the

main hard drive, CD ROM, etc?

•If a plug has been inadvertently connected in an off-set or reversed position, unplug

the AC power source, reconnect the offending connectors and then wait for 30

seconds before replug in the AC power source and try again.

Note: If the power supply is still unable to power up after following the above

instruction, please send the unit back to your dealer or retailer for after sales

service.

Condition 2:

Trouble Shooting

J

14

I

Other Specification

Advertising
This manual is related to the following products: