INSTALLATION
1. Attach the 2967-585 adjustment plate to the coulter arm using 2) ½” x 1 ¼” bolts and lock
nuts.
2. Remove the ½” x 5” bolt which attaches the coulter arms to the mounting brackets
through the slot. Save the ½” lock nut and the ½” flat washers for later use.
CAUTION: DO NOT USE SPACER STRAP ON COMBO ARM W.A. AS A
HANDLE, FINGERS MAY BE SERIOUSLY INJURED ON SHARP EDGE OF
BLADE. USE ½” SQ. DRIVE SOCKET TOOLS TO ADJUST THIS PART.
3. Assemble the 2967-190 Residue Manager wheel/arm assembly to the coulter with the ½”
x 8” bolt and 2967-586 spacers. Use the ½” locknut and flat washers removed in step 1.
Tighten this bolt securely. The ½” x 8” bolt must be through the TOP hole of the coulter
arms.
4. Check the alignment of all holes in the 2967-280 combo arm and the 2967-585
adjustment plate with the combo adjustment pin. Securely tighten all bolts.