50

TROUBLESHOOTING



PROBLEM
Poor overall performance







Toolbar height too high





Shallow knife penetration











Disc Sealer blade & hub fall
off


Disc Sealer not creating a
mound or too small of a
mound

















CAUSE
Toolbar not adjusted correctly




Unit is not set correctly


Too much down pressure
spring tension

Toolbar gauge wheels
adjusted too low

Speed too slow

Toolbar height too high



Insufficient down pressure





Washer not installed in the
disc assembly.


Speed too slow



Blades are not set
aggressively enough


Down pressure spring is loose



Toolbar is not level-probably
nose down






SOLUTION
Adjust the toolbar so that
during operation it is level and
at a height of 24” from the
bottom of the toolbar to the
soil surface.
See Operations section for
proper adjustments

Remove two outer springs &
set in light pressure setting

Raise gauge wheels


Operate at 5 mph minimum

Must have toolbar operating
at 24” above the soil surface


Set down pressure spring
adjustment to the rear hole
Inspect springs for breakage
and/or wear
Adjust toolbar height lower.
Normally 24”
See Parts Identification for
proper assembly.


Operate at 5mph minimum



Increase the angle of the front
edge of blade to the row.


Tighten the coil spring by
compressing; tighten the 3/4”
hex nut onto the pushrod.

Level toolbar at a height of
24” from soil surface.