NOTE: Engines with 14 mm long reach

plugs, use long reach adapter.

CAUTION

Do not use long reach adapter

on short reach holes

10. Hand tighten spark plug adapter

hose into a spark plug well

CAUTION

Do not use a wrench to

attach spark plug adapter hose.

11. Connect spark plug adapter hose to

gauge

NOTE: Hose adapter is attached to

gauge by pulling up on outer sleeve of

quick disconnect on gauge and allowing

sleeve to return when hose is inserted.
12. Crank engine until pressure reading

stops rising on gauge.

NOTE: Crank engine at least 4

compression strokes.
13. Record compression reading.

14. Press release valve on side of

gauge

NOTE. Repeat steps 12 through 14 on

the first cylinder
15. Remove gauge from hose.

16. Hand tighten spark plug adapter

hose into a spark plug well

17. Remove hose from spark plug well

18. Repeat steps 10 through 18 for the

rest of the remaining cylinders.

19. Refer to Test Results.

.

Installation of

Compression Gauge

Push Release Valve to

Relieve Pressure

Release Valve