DAVIS GroWeather/EnviroMonitor: Systems Installation User Manual
Page 6

System Installation
Page 6
Industrial System Installation Manual
2. Attach the sensor cables to the appropriate terminals (as shown below) using the wire
colors printed on the circuit board.
A
TTACHING
C
ABLES
✦
The drain wire (the uninsulated shield wire) from each cable con-
nects to the terminal with the triangle next to it.
✦
When using an extension cable, any extra conductors which are not
used at the sensor cable-to-extension cable connection should be
clipped off to avoid problems at any subsequent connections.
✦
When two color codes are listed together, it indicates that two wires
should be used as a single wire. Twist both wires together before
inserting into the terminal.
✦
Color codes in parenthesis indicate any additional wire color assign-
ments for
extension cables
. If using an extension cable to connect to
the SIM, twist both listed wires together before inserting into the ter-
minal. If connecting to the SIM with the sensor cable, ignore the
color code in parenthesis.