Installing the ac breaker bypass slide plate – Outback Power Systems FW-IOB-Q-120VAC Input/Output/Bypass Assembly - Installation Instructions User Manual

Page 8

Advertising
background image

Figure 5: AC Breaker Bypass Slide Plate Installation

Parts:
1. 8-32 X .75 Machine Screw (2)
2. Nylon Washer (4)
3. 8-32 Nylock Nut (4)
4. AC Breaker Bypass Slide Plate (1)
5. FLEXware AC Breaker Bracket (1)

To Assemble:
1. Remove necessary circuit breaker knockouts (per IOB kit).
2. Install AC Breaker Bypass Slide Plate and fasteners as shown in Figure 5.
3. Do not over tighten the Nylock nuts. Overtightening can cause the AC Breaker Bypass Slide Plate
to bind.

Installing the AC Breaker Bypass Slide Plate

European Sales Office

Barcelona, España

(+34) 600-843-845

19009 62nd Avenue NE

Arlington, WA USA
(+1) 360-435-6030

www.outbackpower.com

900-0073-01-00 REV B

Advertising