Figure 8 – Outback Power Systems MATE Serial Communications Guide User Manual
Page 10

Mate Serial Communication Guide
Copyright 2007
© OutBack Power Systems, Inc.
19009 62
nd
Ave NE, Arlington WA 98223 USA
Page 10
of 20
Rev 4.04 10/21/08 Tel 360 435 6030 Fax 360 435 6019
Warning modes: ‘000’ to ‘255’ This is an ASCII expression of
an 8 bit byte, with each bit representing a different error.
Referring to Figure 8, a returned ‘010’ would be AC input low
voltage and freq. FXs with warnings will continue to operate.
See figure 8.
Chksum: ‘000’ to ‘999’. This is a simple additive chksum of the decimal values of the Status page.
Example:
0,00,00,00,119,000,00,00,000,01,254,008,000,031
0+0+0+0+0+0+0+1+1+9+0+0+0+0+0+0+0+0+0+0+0+1+2+5+4+0+0+8+0+0+0=031
0,00,00,00,120,000,00,02,000,01,254,008,000,025
0+0+0+0+0+0+0+1+2+0+0+0+0+0+0+0+2+0+0+0+0+1+2+5+4+0+0+8+0+0+0=025
BIT # Value Warning
1
1 AC Input Freq High
2
2 AC Input Freq Low
3
4 Input VAC High
4
8 Input VAC Low
5
16 Buy Amps > Input size
6
32 Temp sensor failed
7
64 Comm Error
8
128 Fan Failure
Figure 8