Log screens, Mate/mate2 screens – Outback Power Systems FLEXmax 80 Owners Manual User Manual
Page 77

MATE/MATE2 Screens
900-0009-01-00 Rev
C
75
LOG Screens
Figure 84
LOG Screens
Navigation for STATUS/CC/LOGS
<STATUS> returns to the CC/PG2 screen.
<DOWN> moves to the next menu item
in the diagram.
<UP> moves to the previous menu item
in the diagram.
<TOP> returns to the 1
st
CC/LOG1 screen
for the port shown.
<PORT> directs the MATE to read the
next device (port) on the HUB.
<DAY–> displays log information from
one day earlier. Logs can be displayed
from as far as 128 days in the past.
<DAY+> displays log information from
one day later. If the present day is
displayed, then pressing this key will
return the log to 128 days in the past.
STATUS/CC/METER----P00
end of cc logs display
TOP STATUS
STATUS----------------
choose device
FX CC DC MAIN
MAIN------------------
1:35:04p
SUM STATUS SETUP ADV
STATUS/CC/PAGE1
MODE METER SETPT PG2
STATUS/CC/PAGE2-------
PG1 LOGS STAT MAIN
STATUS/CC/LOG1-----P00
TODAY 0 AH 00.0 kWH
21Vp 00.0Ap 0.00kWp
DOWN DAY- DAY+ PORT
STATUS/CC/LOG2-----P00
TODAY battery
max 14.5V min 14.4V
DOWN DAY- DAY+ PORT
STATUS/CC/LOG3-----P00
TODAY absorb float
00:00 00:00
DOWN DAY- DAY+ PORT
Charge Controller Logs
The LOG screens contain information
collected from the FLEXmax on individual
days. These logs include daily accumulated
amp-hours and kilowatt-hours, and peak
readings for power, current, and voltage. It
also includes the timers for the FLEXmax
battery charger. This data is the same as
that shown on the FLEXmax End-of-Day
Summary screen (see page 18.)
Log 1 Today:
AH (accumulated battery amp-hours)
Kwh (accumulated battery
kilowatt-hours)
Vp (peak PV voltage)
Ap (peak PV current)
kWp (peak PV kilowatt-hours)
Log 2 Today:
max V (maximum battery voltage)
min V (minimum battery voltage)
Log 3 Today:
absorb timer
float timer