Log screens, Mate/mate2 screens – Outback Power Systems FLEXmax 80 Owners Manual User Manual

Page 77

Advertising
background image

MATE/MATE2 Screens

900-0009-01-00 Rev

C

75

LOG Screens

Figure 84

LOG Screens

Navigation for STATUS/CC/LOGS

<STATUS> returns to the CC/PG2 screen.
<DOWN> moves to the next menu item

in the diagram.

<UP> moves to the previous menu item

in the diagram.

<TOP> returns to the 1

st

CC/LOG1 screen

for the port shown.

<PORT> directs the MATE to read the

next device (port) on the HUB.

<DAY–> displays log information from

one day earlier. Logs can be displayed
from as far as 128 days in the past.

<DAY+> displays log information from

one day later. If the present day is
displayed, then pressing this key will
return the log to 128 days in the past.

STATUS/CC/METER----P00
end of cc logs display

TOP STATUS

STATUS----------------
choose device

FX CC DC MAIN

MAIN------------------
1:35:04p

SUM STATUS SETUP ADV

STATUS/CC/PAGE1


MODE METER SETPT PG2

STATUS/CC/PAGE2-------


PG1 LOGS STAT MAIN

STATUS/CC/LOG1-----P00
TODAY 0 AH 00.0 kWH
21Vp 00.0Ap 0.00kWp
DOWN DAY- DAY+ PORT

STATUS/CC/LOG2-----P00
TODAY battery
max 14.5V min 14.4V
DOWN DAY- DAY+ PORT

STATUS/CC/LOG3-----P00
TODAY absorb float
00:00 00:00
DOWN DAY- DAY+ PORT

Charge Controller Logs

The LOG screens contain information
collected from the FLEXmax on individual
days. These logs include daily accumulated
amp-hours and kilowatt-hours, and peak
readings for power, current, and voltage. It
also includes the timers for the FLEXmax
battery charger. This data is the same as
that shown on the FLEXmax End-of-Day
Summary
screen (see page 18.)

Log 1 Today:

AH (accumulated battery amp-hours)
Kwh (accumulated battery

kilowatt-hours)

Vp (peak PV voltage)
Ap (peak PV current)
kWp (peak PV kilowatt-hours)

Log 2 Today:

max V (maximum battery voltage)
min V (minimum battery voltage)

Log 3 Today:

absorb timer
float timer

Advertising