61180009L1-5D

Issue 4, May 2006

3

2. Hold the Dual LIU by the front panel while

supporting the bottom edge.

3. Align the Dual LIU card edges to the guide

grooved for the slot designated

LIU-A

.

4. Insert the Dual LIU until the edge connector seats

firmly into the backplane.

5. Push the ejector in place to ensure the Dual LIU is

fully seated.

NOTE

An additional

LIU-B

slot is also provided for

optional redundancy. For dual operation, only
Dual LIUs of the same software revision
should be installed.

When the Dual LIU first powers up it performs the
power up self-tests, which check the DRAM and
checksum. Once the power up self-test is complete, the
status LEDs will reflect the true state of the hardware.

Front Panel LEDs
The front panel LEDs provide status and alarm infor-
mation. See

Table 2

for LED descriptions.

Front Panel Pushbutton
A pushbutton switch labeled

STATUS

is accessible

from the front panel to aid in test and troubleshooting.
The

MONITOR TX

and

RX

bantam jacks are provided

for T1 access.

NOTE

TX

= Transmit (Out) and

RX

= Receive (In)

Table 2. Front Panel LEDs

Label

Condition

Description

A

Red

Yellow

Green

Flashing

Off

ON = T1-A in Red Alarm

ON = T1-A in Yellow Alarm

ON = T1-A Active

FLASHING = T1-A in Test

OFF = In Monitor Mode

B

Red

Yellow

Green

Flashing

Off

ON = T1-B in Red Alarm

ON = T1-B in Yellow Alarm

ON = T1-B Active

FLASHING = T1-B in Test

OFF = In Monitor Mode

RED

Red

ON = Monitored T1 in Red Alarm

YEL

Yellow

ON = Monitored T1 in Yellow Alarm

RCV

Red

ON = Monitored T1 bipolar or logic error detected

REM

Green

Off

ON = Remotely Provisioned (Craft or Network)

OFF = Locally Provisioned (DIP Switches)

TEST

Yellow

ON = Test Mode Active

MASTER

Green

Flashing

ON = Online Unit

FLASHING = Provisioning in progress. Failover not possible.

STATUS

Switch

Momentary activation cycles through the T1s for monitoring purposes. Activating
the switch for two or more seconds will cause provisioning to toggle between local
and remote.