Troubleshooting a 1.0 g.p.m. Pump:

this should restore most of your prime.

break them free with some WD-40 or something similar and

other. If these 2 pieces are 'stuck' together, you will need to

freely, and they both need to spin INDEPENDENT of each

- Both the counterweight and the bearing need to spin

bearing and counterweight.

- Unscrew (2) screws "S". This will allow you to inspect the

Periodically take the screen at this location out and clean it.

solution in the tank will be away from this inlet location.

may need to tilt the tank backwards a little bit so any

tank should be empty while performing this, otherwise you

this screen. (see exploded view later in this manual) The

tank. You will need to unscrew the knurled nut to access

- Check line strainer (screen) at the inlet location, at the

Pump runs, but does not prime:

know that your lead wire assembly needs to be replaced.

volts to the pump. If your pump runs after doing this, you will

them together. This will insure you are getting the full 12

screwed to the rocker switch, off of the switch and twist

screws, and 'hot-wire' it together. Take the (2) wires that are

the lead wire assembly (#5274443) with the (2) phillips head

Another thing you can try is to take apart the switch box on

when you do this, you know you will need to replace your

pressure switch cap before doing this) If your pump runs

over and touch terminal "B". (You will need to remove the

of the spade terminal of the pressure switch, and cross it

If none of the above will work, try pulling wire terminal "A" off

- Insure a tight connection at the battery clips.

- Make sure you 12 volt source (battery) is fully charged.

- Make sure BOTH on/off switches are in the 'on' position (-).

replace with new fuse. (5 Amp mini-blade fuse...#5157204)

- Check inline fuse on the wires on the pump. If blown,

Pump will NOT run:

pressure switch.

Pump Assembly w/Pressure Switch
Pressure Switch w/Diaphragm

Qty

5095202
5157204
5275531

5157201
5157207

2

4.1

3.1

3

Item

No

1

1

1

1

1

Number

Part

1

5 Amp Mini Fuse

Rocker Switch

Pump Foot (Pkg. of 4)

Description

"B"

Bearing

"S"

List

Price

3.99

37.95
23.95

6.99

4.99

3.1

4.1

1

screw (Factory Preset)

Pressure adjustment

3

counterweight

"Half-Moon"

2

1

(12 Volt, 4 Amp, 1.0 gpm, 35 psi)

#5275702 Pump

Page 2

Winter Storage

Drain all water out of your sprayer, paying special

attention to the pump, handgun, and valve(s). These items

are especially prone to damage from chemicals and

freezing weather.

The sprayer should be winterized before storage by

pumping a solution of RV antifreeze through the entire

plumbing system. This antifreeze solution should remain in

the plumbing system during the winter months. When

spring time comes and you are preparing your sprayer for

the spray season, rinse the entire plumbing system out,

clearing the lines of the antifreeze solution. Proper care

and maintenance will prolong the life of your sprayer.

After Spraying

After use, fill the sprayer tank part way with water. Start the

sprayer, and allow the clear water to be pumped through

the plumbing system and out through the spray nozzles.

Refill the tank about half full with plain water and use

FIMCO Tank Neutralizer and Cleaner, and repeat cleaning

instructions above.

Flush the entire sprayer with the neutralizing/cleaning

agent, then flush out one more time with plain water. Follow

the chemical manufacturer's disposal instructions of all

wash or rinsing water.

For the boom, (if applicable) remove the tips and screens

from the nozzle assemblies. Wash these items out

thoroughly. Blow the orifice clean and dry. If the orifice

remains clogged, clean it with a fine bristle (NOT WIRE)

brush, or with a toothpick. Do not damage the orifice. Water

rinse and dry the tips before storing.
WARNING: Some chemicals will damage the pump

valves if allowed to soak untreated for a length of time!

ALWAYS flush the pump as instructed after each use.