Plumbing operation, Fig. 16 – Ag Spray Equipment 8650 Series Sprayer User Manual

Page 8

Advertising
background image

7 - 8 6 5 0 S E R I E S S P R A Y E R S O P E R A T I O N & M A I N T E N A N C E M A N U A L

FIG. 16

1. Connect supply hose to quick fill valve (valve 3) (If

top filling, open lid and insert supply hose.)

“WARNING!” Be careful if crawling on sprayer. Steel surfaces

can become slick when wet. Also watch head while climbing

onto sprayer if in transport position. Operator must go under

boom to access platform.

2. Make sure main tank valve (valve 1) is open. NOTE:

Make sure rinse tank valve (valve 10) is closed before

filling. Rinse tank could over run and become

chemically contaminated otherwise.

3. Open supply valves and quick fill valve (valve 3) and

start filling sprayer.

4. Start sprayer pump and begin circulating solution.

(NOTE: make sure sprayer booms are off) Make

sure Agitation/Rinse valve is turned with Arrow

pointing downward for agitation and agitation valves

(valve 11 and valve 12) are open.

5. Make sure manual pressure gauge located on

sprayer hand rail has a minimum of 40PSI and

not to exceed maximum of 85PSI while filling.

6. With a minimum of 1/2 tank of solution begin to add

chemical.

OPTIONAL INDUCTOR: Pull transport pin, release safety latch

and gently lower to bottom position. Open Inductor activation

valve (valve 8) to start venturi vacuum. Add pre-determined

chemical amount to inductor tank and then open inductor tank

valve (valve 9) to allow chemical to be pulled into sprayer. (for

dry or heavy viscosity products once premeasured, add some

solution by opening inductor rinse valve (valve 7) 1/8 turn or as

needed to make into a slurry for more efficient induction.) Once

chemical has been drawn out open inductor rinse valve (valve

7) 1/4 turn or as needed to rinse chemical residue down for 1

minute or as needed. Close inductor rinse valve (valve 7) once

tank is empty close inductor tank valve (valve 9). Repeat above

until all chemical is added. When done adding all chemical for

spray solution close inductor activation valve (valve 8) and raise

inductor tank to transport position, activate safety latch, insert

transport pin.

NOTE: For inducting dry flowable products, adjust regulating

valve to 60 P.S.I. minimum.

NOTE: Graduation marking on inductor tank are not calibrat-

ed. Do Not Use for measuring chemical. Only to be used as a

reference point.

NOTE: Make sure inductor rinse tank valve (valve 7) is closed

at all times other than when adding chemical.

7. All chemical needs to be added before solution level

reaches 3/4 of desired capacity.

NOTE: Follow all chemical manufacture label instructions.

PLUMBING OPERATION