State Series 301 User Manual

Page 23

Advertising
background image

23

Water

Temperature °F

Time for 1st

Degree Burn

(Less Severe Burns)

Time for

Permanent Burns

2nd & 3rd Degree

(Most Severe Burns)

110
116
116

122
131
140
149
154

(normal shower temp.)

(pain threshold)

35 minutes

1 minute

5 seconds
2 seconds

1 second

Instantaneous

45 minutes

5 minutes

25 seconds

5 seconds
2 seconds

1 second

(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)

VAC

GAS CONTROL VALVE/THERMOSTAT
SETTINGS

GAS CONTROL/TEMPERATURE KNOB

STATUS
LIGHT

IGNITER

120°F

MARK

FIGURE 19A.

Should overheating occur or the gas supply fail to shut off,

turn off the manual gas control valve to the appliance.
NOTE: During low demand periods when hot water is not

being used, a lower thermostat setting will reduce energy

losses and may satisfy your normal hot water needs. If hot

water use is expected to be more than normal, a higher

thermostat setting may be required to meet the increased

demand. When leaving your home for extended periods

(vacations, etc.) turn the temperature dial to its lowest

setting. This will maintain the water at low temperatures

with minimum energy losses and prevent the tank from

freezing during cold weather.

Operating the Temperature Control System

VAC

List of status codes are shown
at top of gas control valve/thermostat.

FIGURE 19B.

Water Temperature Adjustment
The water temperature setting can be adjusted from 55°F
to 155°F. Turn the Gas Control/Temperature Knob to the
desired setting/temperature.
NOTE:

Some models are certified for 180°F outlet
temperatures. See the Data Plate on the front of the
water heater for the maximum outlet temperature.

The temperatures indicated are approximates. The
actual temperature of the heated water may vary.

Operating Modes and Settings

Standard Mode - The controller adjusts the water

heater to maintain the temperature set by the user.

Vacation Setting - The Vacation setting (VAC) sets

the controller at approximately 55°F. This setting is

recommended when the water heater is not in use for a

long period of time. This effectively turns the controller

temperature setting down to a temperature that

prevents the water in the water heater from freezing

while still conserving energy.

Status Light Code
Normal Flashes:

0 Flashes Indicates Control Off/Pilot Out.

1 Flash Indicates Normal Operation.

A solid red light indicates that the gas control

valve/thermostat is shutting down.

Diagnostic Flashes:
If the water heater is not working, look for the following

diagnostic flashes after lighting the pilot. For more details, see

“Status Light and Diagnostic Code Troubleshooting Chart.”
2 Flashes Indicates Thermopile Voltage Low
4

Flashes

Indicates

Overheat

Failure

5 Flashes Indicates Sensor Failure
7 Flashes Indicates Electronic Control Failure
8 Flashes See “Status Light and Diagnostic Code

Troubleshooting Chart.”

Operational Conditions

Condensation
Whenever the water heater is filled with cold water, some

condensate will form while the burner is on. A water

heater may appear to be leaking when in fact the water is

condensation. This usually happens when:
a. A new water heater is filled with cold water for the first time.
b. Burning gas produces water vapor in water heaters, par-

ticularly high efficiency models where flue temperatures

are lower.

c. Large amounts of hot water are used in a short time and

the refill water in the tank is very cold.

Moisture from the products of combustion condense on the

cooler tank surfaces and form drops of water which may fall

onto the burner or other hot surfaces to produce a “sizzling”

or “frying” noise.