Installation – State SSED 5 thru SSED 120 User Manual

Page 8

Advertising
background image

8

REQUIRED ABILITY

Installation and service of this water heater requires ability
HTXLYDOHQWWRWKDWRIDTXDOL¿HGDJHQF\ SDJH LQWKH¿HOGLQYROYHG
Plumbing and electrical work is required.

GENERAL

The installation must conform with these instructions and the local
code authority having jurisdiction and the requirements of the power
company. In the absence of local codes, the installation must comply
ZLWKWKHFXUUHQWHGLWLRQVRIWKH1DWLRQDO(OHFWULFDO&RGH1)3$RU
WKH &DQDGLDQ (OHFWULFDO &RGH &6$ & 7KH 1DWLRQDO (OHFWULFDO
&RGH PD\ EH RUGHUHG IURP 1DWLRQDO )LUH 3URWHFWLRQ$VVRFLDWLRQ
 %DWWHU\PDUFK 3DUN 4XLQF\ 0$ 7KH &DQDGLDQ (OHFWULFDO
&RGHLVDYDLODEOHIURPWKH&DQDGLDQ6WDQGDUGV$VVRFLDWLRQ
(DVW3OHDVDQW9DOOH\5RDG&OHYHODQG2+

1RWH7RFRPSO\ZLWK16)6WDQGDUGLQVWDOODWLRQUHTXLUHPHQWVWKH
ERWWRPRIWKHZDWHUKHDWHUPXVWEHVHDOHGWRWKHÀRRUZLWKDVLOLFRQH
EDVHGVHDODQWRUHOHYDWHGLQFKHVDERYHWKHÀRRU

Do NOT test electrical system before heater is filled with water,
IROORZ WKH 67$57 83 SURFHGXUH LQ WKH 23(5$7,21 VHFWLRQ RI
this manual.

7KHSULQFLSDOFRPSRQHQWVRIWKHKHDWHUDUHLGHQWL¿HGLQWKH)HDWXUHV
DQG&RPSRQHQWVLOOXVWUDWLRQLQ)LJXUH

0,;,1*9$/9(86$*(
Water heaters are intended to produce hot water. Water heated to
a temperature which will satisfy space heating, clothes washing,
dish washing, cleaning and other sanitizing needs can scald and
SHUPDQHQWO\LQMXUH\RXXSRQFRQWDFW6RPHSHRSOHDUHPRUHOLNHO\
to be permanently injured by hot water than others. These include
WKH HOGHUO\ FKLOGUHQ WKH LQ¿UP RU SK\VLFDOO\GHYHORSPHQWDOO\
GLVDEOHG,IDQ\RQHXVLQJKRWZDWHULQ\RXUKRPH¿WVLQWRRQHRIWKHVH
groups or if there is a local code or state law requiring a maximum
water temperature at the hot water tap, then you must take special
precautions. In addition to using the lowest possible temperature
VHWWLQJ WKDW VDWLV¿HV \RXU KRW ZDWHU QHHGV D PHDQV VXFK DV D
MIXING VALVE should be used at the hot water taps used by these
people or at the water heater.

MIXING VALVES for reducing point of use temperature are
DYDLODEOH&RQVXOWDTXDOL¿HGLQVWDOOHURUVHUYLFHDJHQF\)ROORZDOO
PDQXIDFWXUHU¶V ,QVWUXFWLRQV IRU LQVWDOODWLRQ RI WKHVH YDOYHV %HIRUH
changing the factory setting on the thermostat, read the “Temperature
5HJXODWLRQ´VHFWLRQLQWKLVPDQXDO

CONTAMINATED WATER

7KLVZDWHUKHDWHUVKDOOQRWEHFRQQHFWHGWRDQ\KHDWLQJV\VWHP V 
RUFRPSRQHQW V XVHGZLWKDQRQSRWDEOHZDWHUKHDWLQJDSSOLDQFH

Toxic chemicals, such as those used for boiler treatment shall not
be introduced into this system.

3URGXFWVRIWKLVVRUWVKRXOGQRWEHVWRUHGQHDUWKHKHDWHU$OVRDLU
which is brought in contact with the water heater should not contain
any of these chemicals. If necessary, uncontaminated air should be
obtained from remote or outside sources.

CIRCULATING PUMP

)LHOG LQVWDOOHG FLUFXODWLQJ SXPSV VKRXOG EH RI DOO EURQ]H
construction.

TEMPERATURE-PRESSURE RELIEF VALVE

This water heater is provided with a properly rated/sized and
FHUWL¿HG FRPELQDWLRQ WHPSHUDWXUH  SUHVVXUH UHOLHI YDOYH E\ WKH
 PDQXIDFWXUHU7KH YDOYH LV FHUWL¿HG E\ D QDWLRQDOO\ UHFRJQL]HG
testing laboratory that maintains periodic inspection of production of
listed equipment of materials as meeting the requirements for Relief
9DOYHVIRU+RW:DWHU6XSSO\6\VWHPV$16,=‡&6$DQG
WKHFRGHUHTXLUHPHQWVRI$60(

If replaced, the new valve must meet the requirements of local
codes, but not less than a combination temperature and pressure
UHOLHI YDOYH UDWHGVL]HG DQG FHUWL¿HG DV LQGLFDWHG LQ WKH DERYH
paragraph. The new valve must be marked with a maximum set
pressure not to exceed the marked hydrostatic working pressure of
WKHZDWHUKHDWHU SVL N3D DQGDGLVFKDUJHFDSDFLW\QRW
OHVVWKDQWKHZDWHUKHDWHU%WXKURU.:LQSXWUDWHDVVKRZQRQWKH
water heater’s model rating plate.

INSTALLATION