State SDV 75 70 NE/PE User Manual
Page 16

16
fl exible power cord supplied with the unit, see Figure 2. The power
cord supplied may be used only where local codes permit. If local
codes do not permit the use of a fl exible power supply cord:
a.) Make sure the unit is unplugged from wall outlet. Remove screws
and remove control box.
b.) Cut the fl exible power cord, leaving enough to be able to make
connections, the remove the strain relief fi tting from box.
c.) Install suitable conduit fi tting in side of enclosure and then follow
(d.) and (e.) below.
d.) Splice fi eld wiring into existing wiring using code authorized
method (wire nuts, etc.).
e.) Be certain that neutral and live connections are not reversed
when making these connections.
f.) Replace control box, make sure that the control box is secured shut.
VENT CONNECTIONS TO BLOWER ASSEMBLY
Figure 14 shows the typical vent connections.
FIGURE 14.
WIRING SCHEMATIC
DIAGRAM 1.