Installation installation manual, Condensate drain connections – State GTS-140-PIH User Manual

Page 24

Advertising
background image

24

Page

Installation

Installation Manual

WARNING

Discharge condensate (acidic water) in accordance with all local codes

and common safety practices.

Condensate

drain port

1/2" Condensate

drain tube

Adequate space

Drain

1/2" FPT x 3/8" MPT

(Included with

Neutralizer accessory)

Neutralizer cartridge

(Included with

Neutralizer accessory)
3/8" MPT x 1/2" HB

(Included with

Neutralizer accessory)

Drain

3/8" or 1/2"

Condensate

drain tube

Condensate

drain port

1/2"

FPT x 3/8"

(or 1/2") HB

Adequate space

Case A

Case B

-Condensate Drain Connections-

The water heater is a high efficiency condensing

model

that produces condensate (acidic water)

The

acidic condensate generated in the secondary heat exchanger can be neutralized by the Neutralizer acces-

sory

Case A: If a neutralizer is not required

1 Connect a 1/2” FPT X 3/8” (or 1/2”) HB Adaptor to the condensate drain port at the bottom of the

water heater

2 Connect a condensate drain tube to the 1/2” FPT X 3/8” (or 1/2”) HB Adaptor The manufacturer

recommends the material of the condensate tube be either EPDM or PVC

3 Leave an adequate amount of space between the end of the drain tube and the actual drain, to

facilitate proper drainage

Case B: If a neutralizer is required (installing the Neutralizer assembly)

1 Connect the 1/2” FPT X 3/8” MPT Adaptor to the condensate drain port at the bottom of the water

heater

2 Connect the Neutralizer to the 3/8” MPT connection of the adaptors There is a flow direction indicator

on the neutralizer Please orient the neutralizer in the proper direction

3 Connect a 1/2” drain tube to the other end of neutralizer

4 Leave an adequate amount of space between the end of the drain tube and the actual drain, to

facilitate proper drainage